Features

Complies to CE-Mark standards and is ETL Marked and SEMI F47 compliant

Protection circuits safeguard the amplifiers from over-voltage, over-current and over-power operating conditions

Gain-control circuitry stabilizes output power against line and load variations, and limits power during high VSWR conditions

Unique power monitoring in the low-frequency section measures delivered power into any impedance load

Optional phase locked output in the low- frequency section eliminates the need for a matching network in many applications

Applications

This solid-state generator is ideal for plasma applications including bias, etch, deposition and ashing in semiconductor processing, as well as photovoltaic applications. 

‌Specifications

  • AC input voltage: 187-229 VAC; three phase; 50/60 Hz

  • Line current protection: 20A

  • Analog setpoint and readback levels: 0-10VDC for 0-100% rated power

  • Over-temperature fault: Output disabled when heatsink temp exceeds 60 degrees C

  • Control signals' input impedance: 100k ohms, minimum • Control signals' input isolation: 100VAC minimum to AC supply line • Output power control linearity: 2% or better

  • Forward/Delivered power regulation: +/- 2% of setpoint for load var. within VSWR foldback limits

  • Load mismatch: Output limited to 200 watts under high VSWR conditions

  • Line regulation: +/- 1% output change over 187-229VAC line voltage

  • Control I/O connector: 15-pin subminiature D type

  • Standard available output connector: N or C

  • Cooling: CDX 2000: 1.5 GPM (5.7 liters)

  • Size: 7"H x 19"W x 19"D (17.8cm x 48.3cm x 48.3cm)

  • Weight: 97 lbs. (44 kg)

Options

HF Section:

Output power: CDX 1000: 600 watts max. continuous into 50-ohm load, CDX 2000: 1000 watts max. continuous into 50-ohm load

Frequency: Any fixed frequency from 2 to 60 MHz

Frequency stability: +/- 0.005%

Harmonic distortion: All harmonics minimum -30dB with respect to fundamental from 10-100% output power

LF Section:

Output power: CDX 1000: 600 watts max. continuous into 50-ohm load, CDX 2000: 1000 watts max. continuous into 50-ohm load

Frequency: Any fixed frequency from 20 kHz to 13.56 MHz or 10% variable

Frequency stability: +/- 1% • Harmonic distortion: All harmonics minimum -40dB with respect to fundamental from 10-100% output power